Tamura OVS-12E Power Supply with 91-264VAC Input, 12 V/0-5 A Single Output Power Supply with Optional Cover Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- None Available
Specifications
- AC Input Voltage Rating: AC100 - 230V, 50/60Hz (47 - 63Hz) | AC90 - 264V - E Series | AC90 - 132VAC / AC180 - 264V - F to J Series | (Automatic voltage selection)
- AC Power Fail Signal: Built-in on 5V output models only, other voltages optional | Power Good Logic “0” | Power Fail
- Current Sharing: Current sharing capability available by using CS terminal and external circuit
- DC Input Voltage Range: DC115 - 372V - E Series | DC230 - 372V - F to J Series with JW1 open
- DC Output Adjustment Range: ± 10% MIN | 24V output: 22.8V to 29.2V
- Efficiency: 70% MIN at nominal line and rated load
- EMI: Meets FCC20780 Part 15J Class B: E, F Series | Class A: G, H, J Series | VDE 0871 Class B: E, F Series | Class A: G, H, J Series | VCC1 Class 2: E, F Series | Class 1: G, H, J Series
- Hold-up time: 20msec MIN under nominal line and rated load
- Input Storage Current: 35A MAX for E Series at nominal line (115/230V) cold start | 30A MAX for F to J Series at nominal line (115/230V) cold start
- Insulation Resistance: 50Mohm MIN DC500V (Input - Output)
- Leakage Current: 0.75mA rms MAX
- Line Regulation: ±0.5% MAX under specified input range
- Load Regulation: ±0.5% MAX from no load to full rated load
- Operating Humidity: 10 - 90% RH, non condensing
- Operating Temperature: 0 to +40 deg. C with cover, 0 to +50 deg. C without cover* In either case, the temperature at the center portion on the side of the chassis should be +60 deg. C MAX. For operation above +40 with cover (+50 deg. C without cover) derate linearly to 50% load at +55 deg. C with cover (+65 deg. C without cover). In either case, the temperature at the center portion on the side of the chassis should be +70 deg. C MAX. * Ambient temperature to be measured at 1” above the main transformer.
- Output Ripple and Noise: 3/5 - 15V output 75mVp-p MAX | 24V output 120mVp-p MAX | 28, 48V output 240mVp-p MAX
- Output Transient Response: 1msec MAX over ±2% of rated voltage under 50 - 100% load change
- Output Voltage Rise Time: 100msec MAX, from 10% to 90% of rated output voltage
- Output Voltage Stability: ±0.1% MAX for 8 hours after 20 minute warm-up
- Overload Protection: 120% TYP of rated load, fold-back limiting type
- Overshoot: No overshoot during turn ON/OFF
- OverVoltage Protection: 3V output 3.8 - 4.6V | 5V output 5.7 - 6.7V | 12V output 14.25 - 15.75V | 15V output 17.25 - 18.75V | 24/28V output 31.0 - 34.5V | 48V output 54.0 - 62.0V
- Power Factor Correction: Use Tamura Part Number PFC-500 as an external active filter power supply
- Remote ON/OFF Control: Built-in F, G, H and J Series, 300uA MIN | < 1V for inhibit, > 4.5V (or open) for ON
- Remote/Local Sensing: Build-in
- Safety: Meets UL1950, C22.2 No. 234, EN60950, VDE0805
- Shock: 20msec, 20G (All axis, 3X ea.)
- Storage Humidity: 10 - 95%, non condensing
- Storage Tempearature: -20 to +85 deg. C
- Surge Voltage Test: Meets IEEE587 C62.41 test method with no damage to power supply
- Temperature Coefficient: ±0.03% per deg. C MAX
- Vibration: 10 - 55Hz, 2G (All axis, 1 hour)
- Withstand Voltage: AC 3KV (Input - Output), AC 1.5KV (Input - Chassis ground)
Applications
- None Available
Aliases